DSpace
 

Academic Knowledge Archives of Gunma Institutes >
前橋工科大学(Maebashi Institute of Technology) >
02 研究紀要 >
第18号(2015) >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10087/9640

Title: 溶接接合部の破断を考慮した柱梁耐力比の検討
Other Titles: Study on Column Overdesign Factor in Consideration of the Welded Joint Rupture
Authors: 服部, 駿太
高橋, 利恵
ハットリ, シュンタ
タカハシ, トシエ
Hattori, Syunta
Takahashi, Toshie
Keywords: システム信頼性
溶接部破断
柱梁耐力比
脆性的破壊
Column-Overdesign-Factor
Welded Joint
Brittle Failure
SystemReliability
Issue Date: 10-Nov-2015
Abstract: The safety factor for joints was investigated, which is at the welded joint of the steel structure in consideration of Column-Overdesign-Factor (COF). Considering the rupture of the welded joint in the steel structure, it is difficult to obtain the structural reliability containing brittle failure by general reliability analysis. In order to perform the reliability analysis including the welded joint rupture, these failure modes of the structure were classified to the mutually exclusive events by COF and the welded joint performance. The welded joint strength was predicted by Bayes’ theorem, using the beam strength as a prior distribution and the experiment's results of welded joint strength. As a result, the ratio of failure probability with the welded joint rupture became about 3% of the total failure probability. When it compared to the layer collapse probability, the COF is higher, the ratio of failure probability including the weld joint rupture is increased.
URI: http://hdl.handle.net/10087/9640
Appears in Collections:第18号(2015)

Files in This Item:

File Description SizeFormat
04論文(高橋)(最終).pdf641.9 kBAdobe PDFView/Open

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

DSpace Software Copyright © 2002-2010  Duraspace - Feedback